欢迎进入济南济柴环能燃气发电设备有限公司官网!
当前位置:首页 - 新闻中心 - 公司新闻

公司新闻

影响燃气发电机组启动时间的因素有哪些?

返回 2025.07.25 来源://m.gz-yanye.com 0

  燃气发电机组作为应急供电或分布式能源的重要设备,其启动速度直接影响供电的及时性,尤其在停电应急场景中,启动时间的长短关乎生产安全与生活保障。燃气发电机组的启动时间并非固定数值,而是受设备类型、启动方式、环境条件等多重因素影响,从几秒到数分钟不等,了解其启动过程与影响因素,有助于合理规划机组应用场景。

  As an important equipment for emergency power supply or distributed energy, the start-up speed of gas generators directly affects the timeliness of power supply, especially in power outage emergency scenarios. The length of start-up time is related to production safety and life security. The start-up time of a gas-fired generator set is not a fixed value, but is influenced by multiple factors such as equipment type, start-up method, and environmental conditions, ranging from a few seconds to a few minutes. Understanding its start-up process and influencing factors can help plan the application scenarios of the unit reasonably.

  燃气发电机组的启动流程包含多个依次衔接的环节,各环节的耗时共同构成总启动时间。首先是准备阶段,控制系统接收到启动指令后,需完成自检(如检查机油压力、水箱水位、燃气压力是否正常),这一过程通常需要 5-10 秒,若检测到异常(如机油不足),系统会自动终止启动并发出警报。接着是启动马达带动发动机转动,通过压缩空气或电启动方式使曲轴旋转,直至达到点火所需的转速(通常为 800-1000 转 / 分钟),电启动方式耗时较短,约 3-5 秒,压缩空气启动因需要建立气压,耗时略长(5-8 秒)。点火成功后,发动机进入怠速暖机阶段,此时转速维持在 1000-1500 转 / 分钟,待水温、油温升至适宜范围(水温约 50℃、油温约 40℃),才能逐步加载至额定转速(1500 转 / 分钟或 3000 转 / 分钟),暖机时间根据环境温度差异较大,常温下约 30-60 秒,低温环境(如 - 10℃以下)可能需要 2-3 分钟,若未充分暖机就加载,易造成发动机磨损。最后是并网或供电切换阶段,机组需与电网同步(电压、频率、相位匹配),这一过程约 5-10 秒,整体来看,常规燃气发电机组从启动指令发出到稳定供电,总时间在 1-5 分钟范围内。

  The start-up process of a gas-fired generator set includes multiple sequential links, and the time consumption of each link together constitutes the total start-up time. Firstly, in the preparation stage, after receiving the start command, the control system needs to complete a self check (such as checking whether the oil pressure, water level in the tank, and gas pressure are normal). This process usually takes 5-10 seconds. If an abnormality is detected (such as insufficient oil), the system will automatically terminate the start and issue an alarm. Next, the starter motor drives the engine to rotate, and the crankshaft rotates through compressed air or electric starting until it reaches the required ignition speed (usually 800-1000 revolutions per minute). Electric starting takes less time, about 3-5 seconds, while compressed air starting takes slightly longer (5-8 seconds) due to the need to establish air pressure. After successful ignition, the engine enters the idle warm-up phase, where the speed is maintained at 1000-1500 revolutions per minute. Only when the water temperature and oil temperature reach the appropriate range (about 50 ℃ for water temperature and about 40 ℃ for oil temperature), can it gradually load to the rated speed (1500 rpm or 3000 rpm). The warm-up time varies greatly depending on the ambient temperature, with about 30-60 seconds at room temperature and 2-3 minutes in low temperature environments (such as below -10 ℃). If the engine is not fully warmed up before loading, it may cause engine wear. Finally, during the grid connection or power supply switching phase, the unit needs to synchronize with the grid (voltage, frequency, phase matching), which takes about 5-10 seconds. Overall, the total time for a conventional gas-fired generator set from the start command to stable power supply is within the range of 1-5 minutes.

  不同类型的燃气发电机组,启动时间存在显著差异。小型便携式燃气发电机组(功率 5-50 千瓦)因结构简单、部件轻便,启动流程简化,从启动到供电通常只需 1-2 分钟。这类机组多采用电启动方式,省略复杂的预热环节,适合家庭应急或小型设备临时供电,但其暖机不充分可能影响寿命。中型机组(功率 50-500 千瓦)配置相对完善,包含必要的预热系统,启动时间通常为 2-3 分钟,能在保证机组安全的前提下较快供电,广泛应用于商业建筑、中小型工厂的应急供电。大型燃气发电机组(功率 500 千瓦以上)因发动机体积大、部件惯性强,启动流程更复杂,需经过严格的预热、吹扫(排除缸内可能存在的可燃气体)、同步等步骤,启动时间往往需要 3-5 分钟,但其稳定性高,适合大型工业场所或电网调峰使用。

  There are significant differences in the start-up time of different types of gas-fired generator sets. Small portable gas generator sets (with a power of 5-50 kW) typically take only 1-2 minutes from start-up to power supply due to their simple structure, lightweight components, and simplified start-up process. These types of units often use electric starting methods, omitting complex preheating steps, making them suitable for household emergency or temporary power supply for small equipment. However, insufficient warm-up may affect their lifespan. Medium sized units (with a power of 50-500 kilowatts) are relatively well-equipped, including necessary preheating systems. The start-up time is usually 2-3 minutes, and they can provide power quickly while ensuring the safety of the unit. They are widely used for emergency power supply in commercial buildings and small and medium-sized factories. Large gas generator sets (with a power of over 500 kilowatts) require strict preheating, purging (to eliminate possible combustible gases in the cylinder), synchronization, and other steps due to their large engine volume, strong component inertia, and more complex start-up process. The start-up time often takes 3-5 minutes, but it has high stability and is suitable for use in large industrial sites or power grid peak shaving.

  启动方式的选择直接影响燃气发电机组的启动速度。电启动是最常见的方式,通过蓄电池驱动启动马达带动发动机,启动响应快(3-5 秒即可带动曲轴转动),但受蓄电池电量影响,低温环境下若电量不足,可能出现启动失败,需配备蓄电池保温装置或备用电源。压缩空气启动则利用高压空气(压力通常为 0.6-0.8MPa)推动气动马达,适合大型机组,启动扭矩大,不受低温影响,但需提前储备压缩空气,充气过程会增加整体启动时间。全自动启动方式(搭配 ATS 自动转换开关)能进一步缩短响应时间,当检测到电网断电后,系统会在 1-2 秒内发出启动指令,比手动启动节省操作时间,尤其适合无人值守的应急场景,从断电到机组供电的总时间可控制在 3 分钟以内。

  The choice of starting method directly affects the starting speed of the gas generator set. Electric starting is the most common method, which uses a battery to drive the starter motor to drive the engine. The starting response is fast (3-5 seconds can drive the crankshaft to rotate), but due to the influence of battery power, if the battery power is insufficient in low-temperature environments, starting failure may occur, and battery insulation devices or backup power sources need to be equipped. Compressed air start-up uses high-pressure air (usually 0.6-0.8MPa) to drive the pneumatic motor, which is suitable for large units with high starting torque and is not affected by low temperatures. However, compressed air needs to be reserved in advance, and the inflation process will increase the overall start-up time. The fully automatic start mode (combined with ATS automatic transfer switch) can further shorten the response time. When a power outage is detected, the system will issue a start command within 1-2 seconds, saving operation time compared to manual start, especially suitable for unmanned emergency scenarios. The total time from power outage to unit power supply can be controlled within 3 minutes.

base64_image

  环境条件对燃气发电机组的启动时间有不可忽视的影响。低温环境(低于 0℃)会导致机油粘度增加、蓄电池容量下降,发动机转动阻力增大,启动马达带动曲轴达到点火转速的时间延长,可能比常温下增加 50% 以上,此时需启用预热系统(如缸体加热器、进气预热器),预热时间通常为 1-3 分钟,虽增加了启动总时间,但能保证启动成功率。高温高湿环境(温度超过 35℃、湿度超过 85%)会影响燃气与空气的混合比例,可能导致点火延迟或启动后转速波动,需通过调整空燃比补偿,启动时间会增加 10%-20%。高海拔地区(海拔超过 1000 米)因空气稀薄,发动机进气量不足,启动时可能需要多次尝试才能成功,启动时间比平原地区延长 20-30 秒,且需对化油器或燃气喷射系统进行改装,以适应低气压环境。

  The environmental conditions have an undeniable impact on the start-up time of gas-fired power generation units. Low temperature environment (below 0 ℃) can cause an increase in oil viscosity, a decrease in battery capacity, an increase in engine rotational resistance, and a longer time for the starter motor to drive the crankshaft to ignition speed, which may be more than 50% longer than at room temperature. At this time, preheating systems (such as cylinder block heaters and intake preheaters) need to be activated, and the preheating time is usually 1-3 minutes. Although it increases the total starting time, it can ensure the success rate of starting. High temperature and high humidity environment (temperature exceeding 35 ℃, humidity exceeding 85%) can affect the mixing ratio of gas and air, which may cause ignition delay or speed fluctuation after starting. It is necessary to compensate by adjusting the air-fuel ratio, and the starting time will increase by 10% -20%. In high-altitude areas (over 1000 meters above sea level), due to thin air and insufficient engine intake, multiple attempts may be required to successfully start the engine. The start-up time is 20-30 seconds longer than in plain areas, and the carburetor or gas injection system needs to be modified to adapt to low-pressure environments.

  维护状况良好的燃气发电机组,启动时间更稳定且偏短。发动机若长期未保养,机油变质会增加摩擦阻力,滤芯堵塞会导致进气、供油不足,启动时可能出现 “启动困难”(多次尝试才能成功),使启动时间延长甚至翻倍。启动系统部件(如启动马达、电磁阀)的磨损,会导致启动动力不足,曲轴转速难以达到点火要求,需更换部件才能恢复正常启动速度。相反,定期更换机油、清理滤芯、检查启动系统的机组,各环节运行顺畅,启动时间能保持在设计范围内,减少意外延误。

  A well maintained gas generator set has a more stable and shorter start-up time. If the engine is not maintained for a long time, the deterioration of the engine oil will increase frictional resistance, and the blockage of the filter element will lead to insufficient intake and fuel supply. During startup, there may be "difficulty starting" (multiple attempts are required to succeed), which can prolong or even double the startup time. The wear and tear of components in the starting system (such as the starter motor and solenoid valve) can lead to insufficient starting power and difficulty in achieving the required crankshaft speed for ignition. Replacement of these components is necessary to restore normal starting speed. On the contrary, regularly changing the engine oil, cleaning the filter element, and checking the starting system of the unit can ensure smooth operation in all aspects and keep the starting time within the design range, reducing unexpected delays.

  燃气发电机组的启动时间是多种因素共同作用的结果,常规情况下从启动到稳定供电需 1-5 分钟,具体时间需结合机组类型、启动方式、环境条件及维护状况综合判断。在实际应用中,需根据场景对供电及时性的要求选择合适的机组 —— 应急供电(如医院、数据中心)应优先选择启动速度快(3 分钟以内)的中型全自动机组;对启动时间要求不高的常规发电(如养殖场、工厂自备电源),可选择性价比更高的普通机组。同时,做好机组的日常维护与环境适应性改造,能有效保证启动时间的稳定性,确保在需要时及时发挥作用。

  The start-up time of a gas-fired generator set is the result of multiple factors working together. Under normal circumstances, it takes 1-5 minutes from start-up to stable power supply. The specific time needs to be comprehensively judged based on the type of unit, start-up method, environmental conditions, and maintenance status. In practical applications, suitable units should be selected according to the requirements of power supply timeliness in the scenario - emergency power supply (such as hospitals, data centers) should prioritize medium-sized fully automatic units with fast start-up speed (within 3 minutes); For conventional power generation systems that do not require high start-up time (such as farms or factories with their own power sources), more cost-effective conventional units can be chosen. At the same time, carrying out daily maintenance and environmental adaptability modification of the unit can effectively ensure the stability of the start-up time and ensure timely effectiveness when needed.

  本文由燃气发电机组友情奉献.更多有关的知识请点击://m.gz-yanye.com我们将会对您提出的疑问进行详细的解答,欢迎您登录网站留言.

  This article is a friendly contribution from a gas generator set For more information, please click: //m.gz-yanye.com We will provide detailed answers to your questions. You are welcome to log in to our website and leave a message

新闻搜索
济南济柴环能燃气发电设备有限公司
  • 服务热线

    0531-62325028
    0531-69951266

影响燃气发电机组启动时间的因素有哪些?

  燃气发电机组作为应急供电或分布式能源的重要设备,其启动速度直接影响供电的及时性,尤其在停电应急场景中,启动时间的长短关乎生产安全与生活保障。燃气发电机组的启动时间并非固定数值,而是受设备类型、启动方式、环境条件等多重因素影响,从几秒到数分钟不等,了解其启动过程与影响因素,有助于合理规划机组应用场景。

  As an important equipment for emergency power supply or distributed energy, the start-up speed of gas generators directly affects the timeliness of power supply, especially in power outage emergency scenarios. The length of start-up time is related to production safety and life security. The start-up time of a gas-fired generator set is not a fixed value, but is influenced by multiple factors such as equipment type, start-up method, and environmental conditions, ranging from a few seconds to a few minutes. Understanding its start-up process and influencing factors can help plan the application scenarios of the unit reasonably.

  燃气发电机组的启动流程包含多个依次衔接的环节,各环节的耗时共同构成总启动时间。首先是准备阶段,控制系统接收到启动指令后,需完成自检(如检查机油压力、水箱水位、燃气压力是否正常),这一过程通常需要 5-10 秒,若检测到异常(如机油不足),系统会自动终止启动并发出警报。接着是启动马达带动发动机转动,通过压缩空气或电启动方式使曲轴旋转,直至达到点火所需的转速(通常为 800-1000 转 / 分钟),电启动方式耗时较短,约 3-5 秒,压缩空气启动因需要建立气压,耗时略长(5-8 秒)。点火成功后,发动机进入怠速暖机阶段,此时转速维持在 1000-1500 转 / 分钟,待水温、油温升至适宜范围(水温约 50℃、油温约 40℃),才能逐步加载至额定转速(1500 转 / 分钟或 3000 转 / 分钟),暖机时间根据环境温度差异较大,常温下约 30-60 秒,低温环境(如 - 10℃以下)可能需要 2-3 分钟,若未充分暖机就加载,易造成发动机磨损。最后是并网或供电切换阶段,机组需与电网同步(电压、频率、相位匹配),这一过程约 5-10 秒,整体来看,常规燃气发电机组从启动指令发出到稳定供电,总时间在 1-5 分钟范围内。

  The start-up process of a gas-fired generator set includes multiple sequential links, and the time consumption of each link together constitutes the total start-up time. Firstly, in the preparation stage, after receiving the start command, the control system needs to complete a self check (such as checking whether the oil pressure, water level in the tank, and gas pressure are normal). This process usually takes 5-10 seconds. If an abnormality is detected (such as insufficient oil), the system will automatically terminate the start and issue an alarm. Next, the starter motor drives the engine to rotate, and the crankshaft rotates through compressed air or electric starting until it reaches the required ignition speed (usually 800-1000 revolutions per minute). Electric starting takes less time, about 3-5 seconds, while compressed air starting takes slightly longer (5-8 seconds) due to the need to establish air pressure. After successful ignition, the engine enters the idle warm-up phase, where the speed is maintained at 1000-1500 revolutions per minute. Only when the water temperature and oil temperature reach the appropriate range (about 50 ℃ for water temperature and about 40 ℃ for oil temperature), can it gradually load to the rated speed (1500 rpm or 3000 rpm). The warm-up time varies greatly depending on the ambient temperature, with about 30-60 seconds at room temperature and 2-3 minutes in low temperature environments (such as below -10 ℃). If the engine is not fully warmed up before loading, it may cause engine wear. Finally, during the grid connection or power supply switching phase, the unit needs to synchronize with the grid (voltage, frequency, phase matching), which takes about 5-10 seconds. Overall, the total time for a conventional gas-fired generator set from the start command to stable power supply is within the range of 1-5 minutes.

  不同类型的燃气发电机组,启动时间存在显著差异。小型便携式燃气发电机组(功率 5-50 千瓦)因结构简单、部件轻便,启动流程简化,从启动到供电通常只需 1-2 分钟。这类机组多采用电启动方式,省略复杂的预热环节,适合家庭应急或小型设备临时供电,但其暖机不充分可能影响寿命。中型机组(功率 50-500 千瓦)配置相对完善,包含必要的预热系统,启动时间通常为 2-3 分钟,能在保证机组安全的前提下较快供电,广泛应用于商业建筑、中小型工厂的应急供电。大型燃气发电机组(功率 500 千瓦以上)因发动机体积大、部件惯性强,启动流程更复杂,需经过严格的预热、吹扫(排除缸内可能存在的可燃气体)、同步等步骤,启动时间往往需要 3-5 分钟,但其稳定性高,适合大型工业场所或电网调峰使用。

  There are significant differences in the start-up time of different types of gas-fired generator sets. Small portable gas generator sets (with a power of 5-50 kW) typically take only 1-2 minutes from start-up to power supply due to their simple structure, lightweight components, and simplified start-up process. These types of units often use electric starting methods, omitting complex preheating steps, making them suitable for household emergency or temporary power supply for small equipment. However, insufficient warm-up may affect their lifespan. Medium sized units (with a power of 50-500 kilowatts) are relatively well-equipped, including necessary preheating systems. The start-up time is usually 2-3 minutes, and they can provide power quickly while ensuring the safety of the unit. They are widely used for emergency power supply in commercial buildings and small and medium-sized factories. Large gas generator sets (with a power of over 500 kilowatts) require strict preheating, purging (to eliminate possible combustible gases in the cylinder), synchronization, and other steps due to their large engine volume, strong component inertia, and more complex start-up process. The start-up time often takes 3-5 minutes, but it has high stability and is suitable for use in large industrial sites or power grid peak shaving.

  启动方式的选择直接影响燃气发电机组的启动速度。电启动是最常见的方式,通过蓄电池驱动启动马达带动发动机,启动响应快(3-5 秒即可带动曲轴转动),但受蓄电池电量影响,低温环境下若电量不足,可能出现启动失败,需配备蓄电池保温装置或备用电源。压缩空气启动则利用高压空气(压力通常为 0.6-0.8MPa)推动气动马达,适合大型机组,启动扭矩大,不受低温影响,但需提前储备压缩空气,充气过程会增加整体启动时间。全自动启动方式(搭配 ATS 自动转换开关)能进一步缩短响应时间,当检测到电网断电后,系统会在 1-2 秒内发出启动指令,比手动启动节省操作时间,尤其适合无人值守的应急场景,从断电到机组供电的总时间可控制在 3 分钟以内。

  The choice of starting method directly affects the starting speed of the gas generator set. Electric starting is the most common method, which uses a battery to drive the starter motor to drive the engine. The starting response is fast (3-5 seconds can drive the crankshaft to rotate), but due to the influence of battery power, if the battery power is insufficient in low-temperature environments, starting failure may occur, and battery insulation devices or backup power sources need to be equipped. Compressed air start-up uses high-pressure air (usually 0.6-0.8MPa) to drive the pneumatic motor, which is suitable for large units with high starting torque and is not affected by low temperatures. However, compressed air needs to be reserved in advance, and the inflation process will increase the overall start-up time. The fully automatic start mode (combined with ATS automatic transfer switch) can further shorten the response time. When a power outage is detected, the system will issue a start command within 1-2 seconds, saving operation time compared to manual start, especially suitable for unmanned emergency scenarios. The total time from power outage to unit power supply can be controlled within 3 minutes.

base64_image

  环境条件对燃气发电机组的启动时间有不可忽视的影响。低温环境(低于 0℃)会导致机油粘度增加、蓄电池容量下降,发动机转动阻力增大,启动马达带动曲轴达到点火转速的时间延长,可能比常温下增加 50% 以上,此时需启用预热系统(如缸体加热器、进气预热器),预热时间通常为 1-3 分钟,虽增加了启动总时间,但能保证启动成功率。高温高湿环境(温度超过 35℃、湿度超过 85%)会影响燃气与空气的混合比例,可能导致点火延迟或启动后转速波动,需通过调整空燃比补偿,启动时间会增加 10%-20%。高海拔地区(海拔超过 1000 米)因空气稀薄,发动机进气量不足,启动时可能需要多次尝试才能成功,启动时间比平原地区延长 20-30 秒,且需对化油器或燃气喷射系统进行改装,以适应低气压环境。

  The environmental conditions have an undeniable impact on the start-up time of gas-fired power generation units. Low temperature environment (below 0 ℃) can cause an increase in oil viscosity, a decrease in battery capacity, an increase in engine rotational resistance, and a longer time for the starter motor to drive the crankshaft to ignition speed, which may be more than 50% longer than at room temperature. At this time, preheating systems (such as cylinder block heaters and intake preheaters) need to be activated, and the preheating time is usually 1-3 minutes. Although it increases the total starting time, it can ensure the success rate of starting. High temperature and high humidity environment (temperature exceeding 35 ℃, humidity exceeding 85%) can affect the mixing ratio of gas and air, which may cause ignition delay or speed fluctuation after starting. It is necessary to compensate by adjusting the air-fuel ratio, and the starting time will increase by 10% -20%. In high-altitude areas (over 1000 meters above sea level), due to thin air and insufficient engine intake, multiple attempts may be required to successfully start the engine. The start-up time is 20-30 seconds longer than in plain areas, and the carburetor or gas injection system needs to be modified to adapt to low-pressure environments.

  维护状况良好的燃气发电机组,启动时间更稳定且偏短。发动机若长期未保养,机油变质会增加摩擦阻力,滤芯堵塞会导致进气、供油不足,启动时可能出现 “启动困难”(多次尝试才能成功),使启动时间延长甚至翻倍。启动系统部件(如启动马达、电磁阀)的磨损,会导致启动动力不足,曲轴转速难以达到点火要求,需更换部件才能恢复正常启动速度。相反,定期更换机油、清理滤芯、检查启动系统的机组,各环节运行顺畅,启动时间能保持在设计范围内,减少意外延误。

  A well maintained gas generator set has a more stable and shorter start-up time. If the engine is not maintained for a long time, the deterioration of the engine oil will increase frictional resistance, and the blockage of the filter element will lead to insufficient intake and fuel supply. During startup, there may be "difficulty starting" (multiple attempts are required to succeed), which can prolong or even double the startup time. The wear and tear of components in the starting system (such as the starter motor and solenoid valve) can lead to insufficient starting power and difficulty in achieving the required crankshaft speed for ignition. Replacement of these components is necessary to restore normal starting speed. On the contrary, regularly changing the engine oil, cleaning the filter element, and checking the starting system of the unit can ensure smooth operation in all aspects and keep the starting time within the design range, reducing unexpected delays.

  燃气发电机组的启动时间是多种因素共同作用的结果,常规情况下从启动到稳定供电需 1-5 分钟,具体时间需结合机组类型、启动方式、环境条件及维护状况综合判断。在实际应用中,需根据场景对供电及时性的要求选择合适的机组 —— 应急供电(如医院、数据中心)应优先选择启动速度快(3 分钟以内)的中型全自动机组;对启动时间要求不高的常规发电(如养殖场、工厂自备电源),可选择性价比更高的普通机组。同时,做好机组的日常维护与环境适应性改造,能有效保证启动时间的稳定性,确保在需要时及时发挥作用。

  The start-up time of a gas-fired generator set is the result of multiple factors working together. Under normal circumstances, it takes 1-5 minutes from start-up to stable power supply. The specific time needs to be comprehensively judged based on the type of unit, start-up method, environmental conditions, and maintenance status. In practical applications, suitable units should be selected according to the requirements of power supply timeliness in the scenario - emergency power supply (such as hospitals, data centers) should prioritize medium-sized fully automatic units with fast start-up speed (within 3 minutes); For conventional power generation systems that do not require high start-up time (such as farms or factories with their own power sources), more cost-effective conventional units can be chosen. At the same time, carrying out daily maintenance and environmental adaptability modification of the unit can effectively ensure the stability of the start-up time and ensure timely effectiveness when needed.

  本文由燃气发电机组友情奉献.更多有关的知识请点击://m.gz-yanye.com我们将会对您提出的疑问进行详细的解答,欢迎您登录网站留言.

  This article is a friendly contribution from a gas generator set For more information, please click: //m.gz-yanye.com We will provide detailed answers to your questions. You are welcome to log in to our website and leave a message

Baidu
map